Check if the motor brake is released.
Disconnect the power and manually move the seat to identify the cause of the issue.
Inspect if the coupling fixing screws are loose.
Verify if there are any foreign objects fallen inside the sliding area.
Check if the motor brake is released.
Disconnect the power and manually move the seat to identify the cause of the issue.
Inspect if the coupling fixing screws are loose.
Verify if there are any foreign objects fallen inside the sliding area.
Typically, standard linear guides can withstand temperatures below 80°C, while those made from high-temperature resistant materials can handle temperatures below 150°C.
Regularly inspect the module, checking the motor and couplings for abnormal vibrations or noise during operation.
Inspect the ball screw, linear guide, and bearings for abnormal vibrations or noise while in operation.
During regular maintenance, check for loose installation screws to ensure the reliability of the linear module.
Periodically clean dust accumulation from photoelectric switches to prevent malfunction.
Inspect visible areas for oil stains, scratches, or unidentified dust.
Regularly lubricate the linear guide and ball screw, and replenish lubricating oil as needed.
Friction occurs between the steel balls and grooves inside the linear module during operation, which can shorten the lifespan of the guide and screw.
Maintenance for the linear guide typically occurs monthly, including adding lubricating oil and cleaning old oil residues with a lint-free or cotton cloth.
Maintenance for the ball screw also occurs monthly, involving adding lubricating oil, cleaning old oil residues, and carefully wiping the nut and grooves with a cloth.
Ruixiang Intelligent linear modules offer optional automatic oil injection systems to ensure continuous operation of production lines without downtime.
Q1: What should be done if there is abnormal noise during machine operation or it cannot operate?
A: First determine if the abnormal noise is throughout the entire operation (go to Q2) or if it is at the motor end (go to Q13), (if unable to operate, go to Q30).
Q2: How should one handle if it is determined to be abnormal noise throughout the entire operation?
A: Check if basic maintenance has been performed.
Q3: What are the key points of basic maintenance?
A: Rail (slider) > Screw (ball screw nut) > Angular contact bearing (FK).
Q4: How should one handle if it is determined that there is an abnormality with the rail (slider)?
A: First, check if there is any collision between the rail and slider.
Q5: What should be done if there is no collision between the rail and slider?
A: Check if the screws are tightened. If tightened, check if the alignment is shifted.
Q6: What should be done if there is no abnormality with the rail (slider)?
A: Check if the balls inside the slider are damaged.
Q7: What should be done if there is no abnormality with the rail (slider)?
A: Check if there is any abnormality with the screw (ball screw nut).
Q8: What are the key points to check with the screw and ball screw nut?
A: First, check if the screw is rusted or scratched on the surface. For the ball screw nut (go to Q9).
Q9: What should be done if there is no abnormality with the screw?
A: Check if the balls inside the ball screw nut are damaged. If not damaged, check if the alignment is shifted.
Q10: What should be done if there is no abnormality with the screw (ball screw nut)?
A: Check if there is any abnormality with the angular contact bearing (FK). The key points to check with FK are the same as for the angular contact bearing.
Q11: What are the key points to check with the angular contact bearing?
A: First, check if there is any foreign object jamming the angular contact bearing. If no foreign object jamming, check if the balls inside are damaged.
Q12: What should be done if there is no abnormality with the angular contact bearing?
A: First, check if there was any misalignment during installation, if the screws are tightened properly, and if there are any damaged balls inside.